Category :
Specific probes (active-Coaxial-Kelvin...)
|
|
|
|
|
|
|
 | Active probe tip for characterization on internal nodes requiring a » frequency range = DC-500MHz » The replaceable probe tip includes a MOS at the input and mounts onto an active arm » The active arm has specific mounting to the micropositioner) » A separate power supply provides power to the probes (up to 2 per power supply) » Several tip shank diameters and radius are available
» High temperature option ++ See all models of active-coaxial-Kelvin probes |
| Models | 710 : Replaceable active tip straight, wire 10µm, tip radius 0.1µm |
| 710-HT : Replaceable high temperature active tip straight, wire 10µm, tip radius 0.1µm |
| 722 : Replaceable active tip straight, wire 22µm, tip radius 1.0µm |
| Search limited to 3 Models / Product |
 | The coaxial Probe is designed for low-level signal probing (<10fA@200°C) » The probe's single unit design is especially desirable for the best possible electrical characteristics » The Coaxial Probe is also offered with optional Ground Plane, Kelvin (see PTA-73APT) and resistor series /parallel configurations » The Probes are constructed of microwave-quality components with a 50 Ohm semi-rigid cable shield being achieved through the utilization a Teflon dielectric » The probe contact protrudes from the shielding by .150" (3mm) to maintain low-level signal noise to the probe » Tips available (replaceable) from 0.5µm to 12.5µm » The connector is a standard SSMC ++ See other models of active-coaxial-Kelvin probes |
| Models | PTA-74CJ0.5 : Coaxial low-level signal probe, tip 0.5 µm |
| PTA-74CJ1 : Coaxial low-level signal probe, tip 1 µm |
| Search limited to 3 Models / Product |
 | The Kelvin Coaxial Probes are designed for low-level signal probing in high-current applications » The Kelvin probe's single unit design is especially desirable for the best possible electrical characteristics and improbes tip control over conventional dual tips design » Resistor series /parallel configurations available in option »
The Probes are constructed of microwave-quality components. The 50 ohm semi-rigid cable consists of 8 mil tungsten wire forming the inner conductor and probe point, with isolation from the gold plated copper shield being achieved through the utilization a Teflon dielectric » The probe contact protrudes from the shielding by .150" (3mm) to maintain low-level signal noise to the probe » Tips available (replaceable) from 0.5µm to 12.5µm » The connector is a standard SSMC ++ See other models of active-coaxial-Kelvin probes
|
| Models | PTA-73APT125-5 : Coaxial low-level signal probe, pitch 12.5 µm, tip 5 µm |
| PTA-73APT250-5 : Coaxial low-level signal probe, pitch 25 µm, tip 5 µm |
| PTA-73APT350-5 : Coaxial low-level signal probe, pitch 35 µm, tip 5 µm |
| Search limited to 3 Models / Product |
 | Active probe tip for characterization on internal nodes requiring a low input capacitance (0.1pF) » frequency range = DC-500MHz » The replaceable probe tip includes a MOS at the input and mounts onto an active arm » The active arm has specific mounting to the micropositioner) » A separate power supply provides power to the probes (up to 2 per power supply) » Several tip shank diameters and radius are available ++ See all models of active-coaxial-Kelvin probes |
| Models | 12C110 : Replaceable active tip straight, wire 10µm, tip radius 0.1µm |
| 12C122 : Replaceable active tip straight, wire 22µm, tip radius 1.0µm |
| 12C135 : Replaceable active tip straight, wire 35µm, tip radius 2.0µm |
| Search limited to 3 Models / Product |
 | Active probe for frequency range DC-350MHz, 0.02pf, aimed to characterization on internal nodes requiring a very low capacitance » The probe tip includes a MOS at the input and mounts onto an active arm which can be mounted on any standard precision micropositioner », A separate power supply can provide power to the probes (up to 2 per power supply) » Several tip shank diameters and radius are available ++ See all models of active-coaxial-Kelvin probes |
| Models | 18C15 : Replaceable active tip straight, wire 5µm, tip radius 0.1µm |
| 18C110 : Replaceable active tip straight, wire 10µm, tip radius 0.1µm |
| 18C120 : Replaceable active tip straight, wire 20µm, tip radius 1µm |
| Search limited to 3 Models / Product |
 | Replaceable low-input-capacitance (0.02pf) active probe tip for characterization on internal sensitive nodes » Frequency range DC-350MHz » The probe tip includes a MOS transistor at the input and mounts onto an active arm (see accessories). The active arm can be mounted on any standard (precision micropositioner) » A separate power supply can provide power to the probes (up to 2 per power supply) » Several tip shank diameters and radius are available ++ See all models of active-coaxial-Kelvin probes |
| Models | 18CHV15 : Replaceable active tip straight, wire 5µm, tip radius 0.1µm |
| 18CHV110 : Replaceable active tip straight, wire 10µm, tip radius 0.1µm |
| 18CHV120 : Replaceable active tip straight, wire 20µm, tip radius 1.0µm |
| Search limited to 3 Models / Product |
 | Active probe for frequency range DC-350MHz, 0.02pf, for characterization on internal nodes requiring a very low capacitance » The probe tip (replaceable) includes a MOS at the input and mounts onto an active arm (see accessories) » The active arm can be mounted on any standard micropositioner » A separate power supply can provide power to the probes (up to 2 per power supply) » Several tip shank diameters and radius are available ++ See all models of active-coaxial-Kelvin probes |
| Models | 19C15 : Replaceable active tip straight, wire 5µm, tip radius 0.1µm |
| 19C110 : Replaceable active tip straight, wire 10µm, tip radius 0.1µm |
| 19C120 : Replaceable active tip straight, wire 20µm, tip radius 1.0µm |
| Search limited to 3 Models / Product |
 | Active probe for frequency range DC-1GHz, 0.04pf, for characterization of integrated circuit » The probe tip (replaceable) includes a MOS at the input and mounts onto an active arm (see accessories) » The active arm can be mounted on any standard micropositioner » A separate power supply can provide power to the probes (up to 2 per power supply) » Several tip shank diameters and radius are available ++ See all models of active-coaxial-Kelvin probes |
| Models | 28510 : Replaceable active tip straight, wire 10µm, tip radius 0.1µm |
| 28520 : Replaceable active tip straight, wire 20µm, tip radius 1.0µm |
| 28550 : Replaceable active tip straight, wire 50µm, tip radius 3.0µm |
| |  | Active probe for frequency range DC-1GHz, 0.04pf, for characterization of integrated circuit » The probe tip (replaceable) includes a MOS at the input and mounts onto an active arm (see accessories) » The active arm can be mounted on any standard micropositioner » A separate power supply can provide power to the probes (up to 2 per power supply) » Several tip shank diameters and radius are available ++ See all models of active-coaxial-Kelvin probes |
| Models | 28510 : Replaceable active tip straight, wire 10µm, tip radius 0.1µm |
| 28520 : Replaceable active tip straight, wire 20µm, tip radius 1.0µm |
| 28550 : Replaceable active tip straight, wire 50µm, tip radius 3.0µm |
| |  | This active probe operates in the range DC to 3GHz (-3dB) and has an input capacitance of 0.1pf for characterization on internal nodes requiring a high input impedance and DC-HF capability » The replaceable probe tip includes a MOS at the input and mounts onto an active arm which can be mounted on any standard precision micropositioner » A separate power supply provides power to the probes (up to 2 per power supply) » Several tip shank diameters and radius are available ++ See all models of active-coaxial-Kelvin probes |
| Models | 34A410 : Replaceable active tip straight, wire 10µm, tip radius 0.1µm |
| 34A422 : Replaceable active tip straight, wire 22µm, tip radius 1µm |
| 34A435 : Replaceable active tip straight, wire 35µm, tip radius 2µm |
| Search limited to 3 Models / Product |
 | This is simply the fastest high impedance probe with single point of contact available on the market operating on the range DC-26GHz with an input capacitance of 0.05pf » It is aimed for characterization on internal nodes requiring a high input impedance and full DC capability » The replaceable probe tip includes a MOS at the input and mounts onto an active arm » The active arm can be mounted on any standard precision micropositioner » A separate power supply (model PS3) provides power to the probes (up to 2 per power supply) » Several tip shank diameters and radius are available ++ See all models of active-coaxial-Kelvin probes |
| Models | 35110 : Replaceable active tip straight, wire 10µm, tip radius 0.1µm |
| 35122 : Replaceable active tip straight, wire 22µm, tip radius 1µm |
| 35135 : Replaceable active tip straight, wire 35µm, tip radius 2µm |
|
|
|
|
|
|
|
|
|
|
|
|
| | | |